How to calculate electricity use for qualifying BICS products

Knowing that a product qualifies is the starting point. The next task is connecting that product to the electricity used at your site. A clear calculation helps turn bills, machine records and production information into an assessment you can explain.

Myriad Energy Relief Vault reduces the time spent preparing an accurate, evidenced and optimised energy relief application. It brings your bills, product information and calculations together, supported by Myriad’s energy specialists.

Guidance reviewed on

The calculation

Use the most recent six consecutive months with available evidence, within the preceding 12 months. Match the period for every figure. Count grid electricity, excluding onsite generation. Use monitoring data where available; otherwise explain and support estimates.

Divide eligible production and allowed supporting electricity by total site grid electricity, then multiply by 100.

Site relief bands are 0% at 25% or less, 50% above 25% but below 50%, and 100% at 50% or more. These exemptions concern covered levies, not the entire bill.

For mixed supporting activities, half their electricity may count where 25% to 50% supports eligible manufacturing; all may count above 50%. Apply these rules separately from the site bands.

Shared meters and existing Supercharger relief require additional adjustments. Do not claim twice for the same electricity.

This allocation is separate from the annual 33,000 kWh minimum. Its evidence test requires more than 16,500 kWh over six months.

Source: Government BICS applicant guidance, sections 2.5 and 4.3 to 4.8 (opens in a new tab).

Build a simple electricity record

Start with a list of your meters, production areas and major electrical equipment. Beside each item, record the relevant products, the source of the electricity figure and any assumptions.

Give each entry a clear purpose. Does it represent a dedicated production line, a shared machine or a supporting service? Keep the supporting calculation alongside the total rather than hiding it in a single unexplained percentage.

For an illustrative machine estimate, average operating demand of 20 kW over 600 hours gives 12,000 kWh. Use a defensible average, not an assumption that the equipment always operates at its maximum rated power. Account for mixed production, idle time and the source of its electricity.

A worked example

Fictional example

The following is a fictional site with one grid meter, no onsite generation and no existing Supercharger relief. All figures cover the same six months. Assume product eligibility and the stated allocations have been verified.

Site grid electricity over the same six months
Electricity categoryGrid use
Direct eligible production72,000 kWh
Shared supporting services48,000 kWh
Other electricity120,000 kWh
Total grid electricity240,000 kWh

None of the other electricity is counted as eligible in this example. Records indicate that 40% of the shared services support eligible production. Applying the supporting activity rule allows half of their electricity to count.

Allowed supporting electricity

48,000 × 50% = 24,000 kWh

Add this to direct eligible production

72,000 + 24,000 = 96,000 kWh

Calculate the eligible share of total site grid electricity

96,000 ÷ 240,000 × 100 = 40%

The site falls in the 50% exemption band. It does not receive a 50% reduction in its entire electricity bill.

Notice that the initial 40% supporting allocation and the final 40% site share happen to be the same in this example. They are separate calculations and should not be confused.

Check before you finish

Reconcile your allocation to the total grid consumption. In the example, the three starting categories total 240,000 kWh. The eligible supporting amount is taken from the 48,000 kWh already included, not added to the site total again.

Check for overlapping bills, inconsistent units, duplicate equipment and unexplained estimates. A production share based on sales value or item counts is not automatically an electricity share. Explain why your chosen method reflects the equipment and activity involved.

Keep an assumptions record so a reviewer can follow each figure back to its source. For complicated supply arrangements, obtain a site specific review rather than applying this simplified example unchanged.